Abstract

We report a novel approach to treatment of an unexpected complication of vertebroplasty. During initial positioning of transpedicular vertebroplasty needles in a 73-year-old woman, we encountered unexpected ease of needle advancement resulting in progression of the needle through the anterior cortex of the thoracic vertebral body. The transpedicular needle advanced into the mediastinum and, presumably, the adventitia of the descending thoracic aorta. Administration of polymethylmethacrylate cement was performed to tamponade bleeding at the time of the procedure and to reduce the risk of potential delayed bleeding complications within the mediastinum. The treatment was successful and the patient had no immediate or delayed complications as a result of the unintended needle advancement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.