Abstract

The commercial success of synthetic phosphodiesterase-5 (PDE-5) inhibitors (viz. sildenafil, vardenafil and tadalafil) for erectile dysfunction (ED) has led to their widespread use as adulterants in dietary supplements (DSs). Reports on adulteration by ED drugs or their analogues in DSs suggest they may cause a serious threat to human health. The problem is becoming more complex as hidden and structurally modified analogues are continuously being reported. To analyse known drugs and their analogues, three commonly used PDE-5 inhibitors, naturally existing icariin and yohimbin, and their 19 analogues were analyzed in this study. They were identified using ion-spray liquid chromatography/tandem mass spectrometry (LC/MS/MS) using multiple reaction monitoring (MRM). This MRM procedure gave a limit of detection of less than 0.02 ng ml−1 for the 24 compounds, selectivity of fragmentation using MRM for 2.5 – 8.5 min in a single run and peak height repeatability of coefficient of variation of 3.9 – 31.8%. An IDA method using the MRM scans to detect the presence of known analytes was set up and added to a built-in library for screening for PDE-5 inhibitors. These MRM experiments were used to trigger product ion scans using a hybrid quadrupole-linear ion trap instrument. The product ion scan was compared and confirmed by a library search of MS/MS spectra acquired from a reference standard. To search for new analogues of PDE-5 inhibitors, a precursor ion scan of an expected ion m/z 283, which was one of the mass fragments from the analogues of sildenafil or vardenafil, was performed and fragmentation of the precursor ion, by combining a precursor ion scan with automatic confirmation using EPI spectra, was acquired. Of the 37 DSs tested, two were eventually found to be adulterated with yohimbin and vardenafil, respectively. The approach proposed in this study would be valuable in characterizing chemical constituents of drug residues and their analogues with identical chemical substructures from complex natural and synthetic sources in DSs using an information-dependent acquisition-enhanced product ion (IDA–EPI) scan.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.