Abstract

Grill wire brush bristle foreign bodies most commonly embed in the oropharynx. Often these bristles can be removed in the clinic; however, on occasion, the patient requires general anesthesia for retrieval because of the gag reflex and difficulty with access and visualization. We report here on 2 cases of patients who underwent successful transoral robotic surgical retrieval of wire bristles from the base of tongue after unsuccessful direct laryngoscopy. Otolaryngologists should be aware of the use of robotic assistance for oropharyngeal foreign body retrieval.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.