Abstract

One of the major problems with the durability of concrete structures is the corrosion of embedded rebar in concrete. Early detection of corrosion can prevent catastrophic failures in structures. In this paper, the electromechanical impedance method (EMI) is used for structural health monitoring (SHM) and non-destructive corrosion diagnostics. Compared to previous methods, a new method with the highest accuracy is proposed to evaluate the electromechanical impedance curves. By using piezoelectric (PZT) sensors in concrete, the sensitivity of these sensors to compressive force is investigated through a series of experiments. Also, by bonding two PZT sensors on reinforcing bars in two different orientations, the behavior of specimens, are consistently compared with the EMI measurements. According to the results, a solution for the detection of the corrosion rate and its direction as well as the period of corrosion initiation is proposed based on the variations of the impedance curve during the corrosion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.