Abstract

Recently, several researches have been progressed on the primary-side control (PSC) methods which decrease the size and cost of the control stage. However, most of the researches have been applied to the flyback converter, and they have some challenges in applying them to the half-bridge (HB) LLC converter due to the large voltage across the secondary leakage inductor of the transformer. In this letter, a new PSC method for the HB LLC converter is proposed to obtain accurate output voltage. In the proposed method, the output voltage is regulated by obtaining the voltage across the primary side of the transformer when the external resonant inductor voltage becomes 0 V. At this time, since the voltage across the transformer secondary leakage inductor is small, the proposed method can accurately regulate the output voltage. A 400 V input and 20 V/85 W output laboratory prototype is built and tested to verify the effectiveness of the proposed PSC method.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call