Abstract

Expressions for the Laplace transforms of reliability and availability functions are obtained for a two-unit system, with different repair times for the units which have failed from online and standby states, and a dead time value for the repair facility by the use of regeneration point technique. The system consists of two-units with one repair facility. The repair facility is not available for a random time immediately after each repair completion. From the Laplace transforms of reliability and availability functions the steady state availability, reliability and mean time to system failure can be obtained.