Abstract

The results presented in this communication show that the conventional configuration adopting a shear vertical wave at 45° of incidence to detect cracks breaking the surface opposite the one on which the inspecting transducer is placed is not optimal when the crack depth is of the order of one wavelength of the inspecting wave or smaller. Angles of incidence proximal to the critical angle of longitudinal wave should be used instead.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.