Abstract

Elevated concentrations of corona ions have been measured in the vicinity of high voltage overhead lines. It is shown that the integrated ion exposure of aerosols in the corona plume is of the order of (x/u)n(x) where n(x) is the ion concentration at distance x downwind from the line and u is the wind speed. Estimated ion exposures are of order 10(11) m(-3) x s, less then 1% of the 10(13) m(-3) x s needed to cause saturation charging of 20 nm aerosols. It is suggested that it is not valid to postulate that AC corona is a health hazard as a consequence of its charging aerosols in the size range 20-125 nm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.