Abstract

In practical applications, there are many optical errors in the parabolic trough concentrators (PTC), such as mirror slope errors and tracking errors. Image detection is a no contact technique that has a potential to diagnose the optical errors at large plants in use. In this study, a CCD (Charge Coupled Device) camera was used to directly observe the absorber, and the images of the flux peaks were successful obtained. The CCD image showed two bright peaks on the outer wall of the tubular absorber. By comparing the CCD image with the simulation results, the concave deformation of the parabolic mirror was diagnosed, and the slope error of the parabolic mirror was figured out. The images also revealed that sun tracking errors can cause a synchronous shift in the flux. The flux image method does not influence the normal operation of PTC and is an on-line method, which facilitates the field application.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.