Abstract

Quantitative-competitive polymerase chain reaction (QCPCR) is a well-optimised and objective methodology for the determination of viral load in clinical specimens. A major advantage of QCPCR is the ability to control for the differential modulation of the PCR process in the presence of potentially inhibitory material. QCPCR protocols were developed previously for CMV, HHV-6, HHV-7 and HHV-8 and relied upon radioactively labelled primers, followed by autoradiography of the separated and digested PCR products to quantify viral load. Whilst this approach offers high accuracy and dynamic range, non-radioactive approaches would be attractive. Here, an alternative detection system is reported, based on simple ethidium bromide staining and computer analysis of the separated reaction products, which enables its adoption in the analysis of a large number of samples. In calibration experiments using cloned HHV-7 DNA, the ethidium bromide detection method showed an improved correlation with known copy number over that obtained with the isotopic method. In addition, 67 HHV-7 PCR positive blood samples, derived from immunocompromised patients, were quantified using both detection techniques. The results showed a highly significant correlation with no significant difference between the two methods. The applicability of the computerised densitometry method in the routine laboratory is discussed.