Abstract
High-frequency ventilation (HFV) has been suggested as an alternative to standard positive-pressure ventilation with positive end-expiratory pressure (PPV/PEEP) in the treatment of infants with hyaline membrane disease. To assess the relative safety and efficacy of HFV, we compared standard PPV to HFV delivered by oscillation (HFO) and HFV delivered by a flow interrupter (HFFI) in a previously validated preterm baboon model of hyaline membrane disease. At necropsy, the livers of several animals were unexpectedly found to have severe fatty change and/or cytoplasmic vacuolization and edema. There was a strong correlation between use of HFO and the development of liver lesions. The hepatic lesion may reflect decreased cardiac output with a concomitant fall in splenic perfusion and/or alterations in normal intrathoracic pressure that increase resistance in the hepatic vasculature. Although the etiology cannot be determined precisely, these data suggest the potential for nonpulmonary complications of HFV in the immature newborn and mandate further investigation before its widespread clinical application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.