Abstract

We report progress in the development of a nondestructive technique to measure bunch rms‐length in the psec range and below, and eventually in the fsec range, by measuring the high‐frequency spectrum of wake field radiation which is caused by the passage of a relativistic electron bunch through a channel surrounded by a dielectric. We demonstrate both experimentally and numerically that the generated spectrum is determined by the bunch rms‐length, while the choice of the axial and longitudinal charge distribution is not important. Measurement of the millimeter‐wave spectrum will determine the bunch rms‐length in the psec range. This has been done using a series of calibrated mesh filters and the charge bunches produced by the 50MeV rf linac system at ATF, Brookhaven. We have developed the analysis of the factors crucial for achieving good accuracy in this measurement, and find the experimental data are fully understood by the theory. We point out that this technique also may be used for measuring fsec bunch lengths, using a prepared planar wake field microstructure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.