Abstract

A direct radioimmunoassay for serum aldosterone was developed using a highly specific sntibody and 8-anilino-1-naphthalene sulfonic acid as a blocking agent to inhibit the binding of aldosterone to serum proteins. 125I-labeled aldosterone was used as the labeled antigen and polyethylene glycol was used to separate antibody-bound and free aldosterone. The minimum detectable concentration was 1.5 pg/tube. There were excellent correlations between the present method and other methods, i.e., 1) a method using tritiated aldosterone, 2) a method using dichloromethane extraction before assay, and 3) a commercial kit method. The intra-assay coefficient of variation was 6.9%, and the inter-assay coefficient of variation was 10.7%. The values found in normal human serum were comparable with those reported using other methods. The present radioimmunoassay eliminates both extraction of aldosterone from serum and chromatographic separation and requires only 0.1 ml of serum for assay.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.