Abstract

This is the first of two papers on a wide pile group. The geology and a geotechnical model of the site are presented, along with the design of a single pile, analysis of a static loading test, and some dynamic tests. Response of the piled foundations comprising 399 bored piles supporting three 70-storey towers on a common mat was monitored. Records consist of results of a static loading test, dynamic tests of four piles, the development of load in 15 piles, and settlement of 40 points during construction and nine years following. At end of construction, the perimeter piles received more load from the towers than did the interior piles and the mat settled on average 90 mm. By the end of the monitoring period, due to the general subsidence, the average settlement of the mat had increased by 50 mm. Most of the settlement is considered to originate from the compression of the soil layers below the pile toe level. A subsequent paper will present the analysis and design of the wide pile group, and the numerical analysis of the static loading test on a single pile and of the wide pile group.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.