Abstract

This paper introduces a new single-phase high power factor rectifier, which features regulation by conventional PWM, soft commutation and instantaneous average line current control. Furthermore, thanks to the use of a single converter, instead of the conventional configuration composed of a four-diode front-end rectifier followed by a boost converter, a significant reduction in the conduction losses is achieved. A prototype rated at 1.6 kW, operating at 70 kHz, with an input AC voltage of 220 Vrms and an output voltage of 400 V/sub DC/ has been implemented in the laboratory. An efficiency of 97.8 % at 1.6 kW has been measured. Analysis, design, and the control circuitry are also presented in the paper.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.