Abstract

BackgroundDifferent mechanical ventilation settings are known to affect lung preservation for lung transplantation. Measurement of particle flow in exhaled air may allow online assessment of the impact of ventilation before changes in the tissue can be observed. We hypothesized that by analyzing the particle flow, we could understand the impact of different ventilation parameters.MethodsParticle flow was monitored in vivo, post mortem, and in ex vivo lung perfusion (EVLP) in six porcines with the Pexa (particles in exhaled air) instrument. Volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) were used to compare small versus large tidal volumes. The surfactant lipids dipalmitoylphosphatidylcholine (DPPC) and phosphatidylcholine (PC) were quantified by mass spectrometry.ResultsIn vivo the particle mass in VCV1 was significantly lower than in VCV2 (p = 0.0186), and the particle mass was significantly higher in PCV1 than in VCV1 (p = 0.0322). In EVLP, the particle mass in VCV1 was significantly higher than in PCV1 (p = 0.0371), and the particle mass was significantly higher in PCV2 than in PCV1 (p = 0.0127). DPPC was significantly higher in EVLP than in vivo.ConclusionsHere, we introduce a new method for measuring particle flow during mechanical ventilation and confirm that these particles can be collected and analyzed. VCV resulted in a lower particle flow in vivo but not in EVLP. In all settings, large tidal volumes resulted in increased particle flow. We found that DPPC was significantly increased comparing in vivo with EVLP. This technology may be useful for developing strategies to preserve the lung and has a high potential to detect biomarkers.

Highlights

  • Different mechanical ventilation settings are known to affect lung preservation for lung transplantation

  • The accumulated particle mass in VCV1 was significantly lower than VCV2 (p = 0.0186), and the accumulated particle mass was significantly higher in PCV1 than in the VCV1 (p = 0.0322)

  • We found that DPPC was significantly increased comparing in vivo with ex vivo lung perfusion (EVLP) late phase

Read more

Summary

Introduction

Different mechanical ventilation settings are known to affect lung preservation for lung transplantation. The lung is known to generate particles in the range of 1 μm or less as well as particles up to around 5–10 μm which are exhaled in the breath These particles are predominantly comprised of surfactants and phospholipids and are thought to originate from the respiratory lining fluid following the opening and closing of the small airways. Monitoring the status of the small airways by analyzing different particle flows online during mechanical ventilation has never been done before, but may provide real-time insight into the effect of changes in mechanical ventilation parameters before changes in conventional parameters can be detected

Methods
Results
Discussion
Conclusion