Abstract

The aim of this study was to test the utility and effectiveness of an alternative computational approach to threshold-intensities based on time dependent change-points in minute ventilation divided by end-tidal partial pressure of CO2 (VE/PETCO2) to reveal whether respiratory compensation point (RCP) is a third ventilatory threshold, or not. Ten recreationally active young adults and ten well-trained athletes volunteered to take part in this study. Following incremental ramp tests, gas exchange threshold (GET) and respiratory compensation point (RCP) were respectively evaluated by the slopes of VCO2-VO2 and VE-VCO2 using the Innocor system automatically. Respiratory threshold (RT) was analysed based on time dependent change-points in the VE/PETCO2 using binary segmentation algorithm. Additionally, those intersections were analysed independently by two experienced investigators using a visual identification technique in a double-blind design. According to the results, in the recreationally active group, there were the first (GET1) and the second (GET2) gas exchange thresholds which were identical with the RT1 (139 W; 1.9 L⋅min−1 of VO2; 1.73 L⋅min−1 of VCO2; 49.9 L⋅min−1 of VE versus 139 W; 1.88 L⋅min−1; 1.7 L⋅min−1; 49 L⋅min−1, respectively) and RT2 (186 W; 2.39 L⋅min−1 of VO2; 2.44 L⋅min−1 of VCO2; 66 L⋅min−1 of VE versus 187 W; 2.41 L⋅min−1; 2.49 L⋅min−1; 65.7 L⋅min−1, respectively). However, there were three threshold intensities which were determined by GET1, GET2, and RCP in well-trained athletes. Additionally, RT1, RT2, and RT3 were determined as valid surrogates of the GET1 (194 W; 2.56 L⋅min−1 of VO2; 1.99 L⋅min−1 of VCO2; 57.5 L⋅min−1 of VE versus 192 W; 2.61 L⋅min−1; 1.99 Lmin−1; 57.7 L⋅min−1, respectively), GET2 (267 W; 3.6 L⋅min−1 of VO2; 3.29 L⋅min−1 of VCO2; 94.5 L⋅min−1 of VE versus 266 W; 3.58 L⋅min−1; 3.26 L⋅min−1; 93.4 L⋅min−1, respectively), and RCP (324 W; 4.05 L⋅min−1 of VO2; 4.13 L⋅min−1 of VCO2; 124 L⋅min−1 of VE versus 322 W; 4.02 L⋅min−1; 4.07 L⋅min−1; 122 L⋅min−1, respectively) in well-trained athletes. There were high levels of agreements between the power outputs determined by traditional techniques and newly proposed change-points in RT. All markers were strongly correlated (p < 0.001). It was shown that RT technique can provide an accurate threshold determination. Furthermore, the RCP was observed as a third threshold-intensity for well-trained athletes but not for recreationally active young adults.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call