Abstract
A thermal technique of rms measurement is described which uses the base-emitter junction of a bipolar transistor to sense the temperature change of a monolithic chip due to the power dissipation of a companion diffused resistor. An analysis is presented which provides: 1) design equations for performing error compensation to minimize the nonlinearity of the rms-to-dc conversion, and 2) ac feedback network design to optimize the low frequency cutoff and settling time product. Resulting rms converters had midband accuracies of /spl plusmn/0.05 percent of full scale over a dynamic range of 30 dB, high frequency limits of 100 MHz for 2 percent accuracy, and settling times less than 1 s.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.