Abstract

A non-destructive, rapid test capable of measuring the air permeability of in situ concrete is described. The technique is based on the application of a hard vacuum to the concrete surface. The rate of pressure recovery is recorded after the vacuum line is disconnected. The experimental results lead to an exponential pressure–time relationship similar to that obtained from analytical solution of Darcy’s equation. The air permeability of concrete can be simply expressed in terms of a vacuum decay parameter, but minor changes in the application of the test make it possible to determine the air permeability of concrete in situ. The test results are sensitive to changes in the parameters that affect the pore structure of concrete, including water–cement ratio, curing conditions, cement content, air content and plasticizing admixtures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.