Abstract

We describe a new method for fixation of dislocated posterior chamber lenses. The closed eye technique involves externalizing the haptics through the pars plana and suturing the loops to the scleral wall. There were no complications in our two patients, and the implants have remained well positioned.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.