Abstract

BackgroundA useful application of flow cytometry is the investigation of cell receptor-ligand interactions. However such analyses are often compromised due to problems interpreting changes in ligand binding where the receptor expression is not constant. Commonly, problems are encountered due to cell treatments resulting in altered receptor expression levels, or when cell lines expressing a transfected receptor with variable expression are being compared. To overcome this limitation we have developed a Microsoft Excel spreadsheet that aims to automatically and effectively simplify flow cytometric data and perform statistical tests in order to provide a clearer graphical representation of results.ResultsTo demonstrate the use and advantages of this new spreadsheet method we have investigated the binding of the transmembrane adhesion receptor CD44 to its ligand hyaluronan. In the first example, phorbol ester treatment of cells results in both increased CD44 expression and increased hyaluronan binding. By applying the spreadsheet method we effectively demonstrate that this increased ligand binding results from receptor activation. In the second example we have compared AKR1 cells transfected either with wild type CD44 (WT CD44) or a mutant with a truncated cytoplasmic domain (CD44-T). These two populations do not have equivalent receptor expression levels but by using the spreadsheet method hyaluronan binding could be compared without the need to generate single cell clones or FACS sorting the cells for matching CD44 expression. By this method it was demonstrated that hyaluronan binding requires a threshold expression of CD44 and that this threshold is higher for CD44-T. However, at high CD44-T expression, binding was equivalent to WT CD44 indicating that the cytoplasmic domain has a role in presenting the receptor at the cell surface in a form required for efficient hyaluronan binding rather than modulating receptor activity.ConclusionUsing the attached spreadsheets and instructions, a simple post-acquisition method for analysing bivariate flow cytometry data is provided. This method constitutes a straightforward improvement over the standard graphical output of flow cytometric data and has the significant advantage that ligand binding can be compared between cell populations irrespective of receptor expression levels.

Highlights

  • A useful application of flow cytometry is the investigation of cell receptor-ligand interactions

  • As fluorescein isothiocyanate (FITC)-hyaluronan binding is strictly dependent on CD44 expression levels, the analysis is compromised where expression levels are not matched

  • Flow cytometry data has been analysed manually to assess levels of hyaluronan binding relative to receptor expression [3,4]

Read more

Summary

Introduction

A useful application of flow cytometry is the investigation of cell receptor-ligand interactions. Problems are encountered due to cell treatments resulting in altered receptor expression levels, or when cell lines expressing a transfected receptor with variable expression are being compared. To overcome this limitation we have developed a Microsoft Excel spreadsheet that aims to automatically and effectively simplify flow cytometric data and perform statistical tests in order to provide a clearer graphical representation of results. The corresponding mean fluorescence intensity for ligand binding is calculated allowing the data set to be presented as a line graph of receptor expression versus ligand binding This method has the advantage of allowing receptor:ligand interactions to be studied over a wide range of receptor expression levels

Methods
Results
Conclusion