Abstract

The complicated resonant operations of class <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\Phi} _{2}$</tex-math></inline-formula> topology bring challenges for accurate design and performance optimization, hindering the full utilization potential of converters. Considering the narrow design freedom in traditional methods with almost fixed duty cycle <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$D$</tex-math></inline-formula> , this article widens the design options of push–pull class <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\Phi} _{2}$</tex-math></inline-formula> converters through frequency-harmonic analysis. A full selection freedom of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$D\in (0,0.5)$</tex-math></inline-formula> is discussed analytically, providing ample space for optimization based on any required performance indices. From 1.98E5 analytical results, we found six numerical equations that fully decouple the interconnected relations between each circuit parameter and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$D$</tex-math></inline-formula> . The proposed numerical method allows rapid circuit design and component selection with a high accuracy regardless of the system power or load voltage. Parasitic effects are discussed and incorporated into the design approach as correction steps. Finally, we introduce performance analysis based on an example wireless power transfer (WPT) system, providing in-depth studies on the optimization regarding efficiency, power output capability, and component selection. Experimental results validate the accuracy and efficiency of the proposed design method based on a 100-W WPT system at 6.78 MHz frequency. Both inverter and rectifier present load-independent soft-switching operations, with converter efficiency over 93%. The system provides 83% dc–dc efficiency at full load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.