Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> This paper presents a new space vector pulsewidth modulation (SVPWM) technique for the control of a six-phase voltage source inverter (VSI)-fed dual stator induction machines (DSIM). A DSIM is an induction machine which has two sets of three-phase stator windings spatially shifted by 30 electrical degrees and fed by two three-phase VSIs. Despite their advantage of power segmentation, these machines are characterized by large zero sequence harmonic currents, and in particular those of order <formula formulatype="inline"> <tex>$6k\pm 1$</tex></formula>, which are due to the mutual cancellation between the two stator windings. The proposed SVPWM scheme, while easy to implement digitally, reduces significantly these extra stator harmonic currents. Experimental results, collected from a 15 kW prototype machine controlled by a digital signal processor, are presented and discussed. </para>