Abstract

Nanoscale phase-variant ultrasound contrast agents have attracted the interest of many researchers. However, it is a challenge to design nanobubbles that are activated by low-frequency medical ultrasound that do not cause damage to normal tissues. In this study, we designed a new type of nanoparticle consisting of perfluoropentane and iron polyphthalocyanine loaded into liposomes. These nanoparticles can be activated by a low-frequency medical ultrasound imager at a frequency of 5 MHz for ultrasound imaging and clear reactive oxygen species at a rate of more than 50%. This ability to scavenge excess reactive oxygen species can alleviate the damage these species cause and protect macrophages. Moreover, these nanoparticles can effectively enhance ultrasound contrast imaging for real-time visualization in the diagnosis and treatment of diseases.