Abstract
A physically and statistically based method for steam generator (SG) heat exchanger tubes (HET) integrity assessment is proposed. The method based is on the stochastic laws of crack dimensions distribution with taking into account its growth, limit load-model of cracked tube, and SG plugging statistics. Based on the history of the tubes, plugging of the specific SG three statistical parameters has to be found: initial number of defects, stochastic parameter of defect depth, and the defect growth rate. The developed method was used for the prediction of HET failure for all Ukrainian SG. It is also used for the justification of pressure reduction of hydrostatic test (HT) for primary circuit of WWER NPPs. It is shown that the pressure reduction from 24.5 to 19.6 MPa for WWER-1000 s and from 19.1 to 15.7 MPa for the WWER-440 s does not practically increase the HET failure probability during operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.