Abstract

Two theoretical problems associated with the measurement of temperature or strain from the normalized power of Brillouin signal in a distributed fiber sensor are studied. One problem is the position-dependent of the coefficient relating the Brillouin power to the local temperature or strain. The other problem is the backward infection of the defect (local temperature or strain change). These two problems will degrade the measurement accuracy of a distributed Brillouin fiber sensor by changing the distribution of pump power. To eliminate these two problems, new reference functions are proposed to normalize the Brillouin signal. Simulation results by using fourth-order Runge–Kutta algorithm show that these new reference functions can eliminate the influence of these two problems on distributed Brillouin fiber sensor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.