A new approach has been developed to detect, characterize, and quantify hydraulic short-circuits in boreholes with faulty seals. The methodology, applicable to an aquifer-aquitard-aquifer system, involves a series of successive, constant-rate pumping tests in the lower aquifer while determining the leakage rate with a simultaneous nonreactive tracer test. During each pumping step, the tracer is injected under constant concentration and constant hydraulic head from a piezometer in the upper aquifer. If a seal defect exists, the tracer will follow the leak and will be recovered from the pumped water. The theoretical equations relate the leakage rate, the pumping rate, the concentration of the injected tracer, and the recovered concentration. Leakage rates can be determined for any pumping rate. The theory is tested using numerical analysis and a full-scale field test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.