Abstract
In the authors' previous work (1997), an original thermal model of transformers with ONAN cooling was developed. The model takes into account the influence of nonlinear thermal characteristics in transient thermal processes; instead of exponential functions and time constants, the numerical solution of differential equations is used. The model delivers one characteristic temperature in copper (solid insulation) and one characteristic temperature in oil. In this paper, the analysis stresses the definition of the hot-spot temperature of the solid insulation by using easily measurable quantities. Then, the parameters of the model can be precisely determined from inexpensive measurements in a short-circuit heating experiment and the model can deliver the hot-spot temperature. The experimental base of this research are the measurements on a 630-kVA, 3 /spl times/ 10 kV/3 /spl times/ 6 kV ONAN transformer equipped with 112 temperature sensors (102 inside the central positioned 10-kV winding).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.