Abstract

A technique for detecting the presence and severity of inter-laminar short circuits and estimating the status of core compression (or looseness) in synchronous generators (or large motors) with single test equipment is proposed in this paper. The core loss measurement obtained from a flux injection probe that injects flux into adjacent teeth over a localized region, is used as an indicator for detecting and distinguishing the two fault conditions. An injection probe system was developed and tested, in the laboratory using stacks of full size generator laminations with various induced fault conditions. The probe was shown to detect the presence of as few as 5 shorted laminations, and to approximately gage the degree of core compression (looseness). A unique differential probe was developed and tested to demonstrate the potential to detect two shorted laminations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.