Abstract

A new method for the removal of metallic canal obstructions is presented. After gaining access to the coronal end of the separated instrument or silver point, a circular groove is prepared around it using ultrasonic tips. A short piece of fine stainless-steel tubing can now be pushed over the exposed end of the object. A Hedström file is pushed in a clockwise turning motion through the tube to wedge between the tube and end of the object. This produces a good interlocking between the separated instrument or silver point, the tube, and Hedström file. The three connected objects can now be removed coronally using relatively high forces. This technique may be more efficient than the endo extractor technique which is using a tube and cyanoacrylate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.