A new protocol is presented for precise measurements of titanium isotopes in natural samples. Titanium was separated via ion-exchange and extraction chromatography in two stages. Tests on Ti standard solutions show that isobaric interferences from Ca, V, and Cr can be adequately corrected, as long as these elements are present at atomic ratios of Ca/Ti < 20, V/Ti < 2, and Cr/Ti < 0.1. Furthermore, Zr2+ and Mo2+ have no influences on Ti+ signals when atomic ratios of Zr/Ti < 0.002 and Mo/Ti < 0.04. Compared with these correction limits, the purified solutions have corresponding ratios several orders of magnitude lower, indicating that the chemical separation technique is effective. This newly developed method has been successfully applied to geostandards and a wide variety of bulk meteorites. Our results are in good agreement with the data from Trinquier et al. (Science, 2009, 324, 374–376)1 and reveal a linear correlation between isotope anomalies of two Ti nuclides in bulk meteorites. The correlation reflects incomplete mixing of the carrier phases for Ti isotope anomalies before bulk meteorite formation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of Analytical Atomic Spectrometry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.