Abstract
A new method for the detection of alternariol (AOH), alternariol monomethyl ether (AME), altenuene (ALT), tentoxin (TEN), and tenuazonic acid (TeA), five alternaria toxins (ATs) was developed by liquid chromatography–triple quadrupole mass spectrometry equipped with atmospheric pressure chemical ionisation (APCI). A single extraction was used to recover the five ATs by apple juices, beers, tomato sauces, olives and dried basil. Different Solid Phase Extractions (SPE) and clean-up were selected to optimise the purification step for each food matrix. Limits of detection and quantification were, respectively, in the range 0.16–12.31 and 0.54–41.04ngg−1. Recovery rates were generally above 70%, except for dried basil and olives. Thirty out of 70 samples analysed (7 apple juices, 14 beers and 9 tomato sauces) resulted positive to at least one alternaria toxin investigated. AOH was the most common AT (14 samples), followed by ALT (10 samples). The highest concentration of ATs was found in commercial apple juices (35.33ngg−1).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.