Abstract
In this study, we developed a simple method for alcohol content analysis in fuel oils by Time-Domain Terahertz (THz) Spectroscopy. Frequency dependent absorption coefficients, refractive indices, and dielectric constants were calculated from the measurements of pure fuel oils and their mixtures with ethanol. Ethanol mixtures of gasoline were modeled successfully with a simple model in which the mixture behavior was described with a basic contribution approach of pure liquids. The results suggest that there is no strong interaction between the ethanol and the molecules in the gasoline. We concluded that this new approach offers a simple and useful method to determine the concentration of ethanol in gasoline currently with a 3% (by volume) maximum absolute error. With improvements, this error would be reduced to below 1%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.