Abstract
Abstract Accuracy of existing measurement models for main steam flow in power plants is always unsatisfied. In this paper, a model with higher accuracy for main steam flow measurement was proposed. Accurate values of main steam flow can be obtained based on principle of mass balance when unit is at a steady state. Because of volume sections such as cooling wall and super heater, this model isn’t suitable for dynamic-state unit. Another measuring model based on Flugel formula can give exact change trends of main steam flow when unit is at a dynamic state. However, its accuracy is unsatisfied. Therefore, this paper took advantages of the two models, fusing them together in frequency domain with complementary filter method. Simulation results show that new model not only gives accurate steam flow when unit is at a steady state but also provides exact change trends of main steam flow.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.