Abstract
ABSTRACTSubsea pipelines are being installed in the Arctic or deeper water. There is an increased interest in improving leak detection system capabilities throughout the pipeline industry. In this paper, a leak detection system with leak detection module and leak location module is developed. Sequential probability ratio test, negative pressure wave method and pressure gradient method are used in this software. Also, a pattern recognition system is embedded in this software to minimise false alarms. The simulation results are well compared with OLGA and PIPESIM results. Based on the test results and the comparisons, it can be demonstrated that the leak detection system proposed in this paper has been proved with a good sensitivity and accuracy. This study can provide a reference for further studies of leak detection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.