Abstract
This paper describes the design and test results of a Kalman filtering based digital distance protection scheme. A brief review of voltage and current Kalman filters is followed by sensitivity analysis due to incorrect model parameters. The complete scheme for fault detection, classification, zone computation, and fault location calculation is tested for all types of faults at different locations using simulated data. The major parts of the scheme were tested using the available recorded data. The test results indicated that the proposed scheme has a mean operating time of a quarter of a cycle, insensitive to incorrect model parameters, and represents a low computer burden.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.