Abstract
The validity of the parameter Br index, which was designed as an indicator of the turbulent noise in breathy voice, was tested. The parameter was determined by the ratio between energy of the second derivative of the high-pass filtered wave and that of the nonderived high-pass filtered wave. The principle of this method is the utilization of the difference in the frequency range between the turbulent noise and other components present. The parameter was found to correlate with the perception of breathiness. Clinical applications of this index suggest the possibility of using it further as a detection tool for diseases that generate turbulent noises.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.