Abstract

SUMMARY A new in vitro assay for thyroid-stimulating hormone (TSH) is described. The parameter of TSH action is the discharge of radioactive iodine from mouse thyroid glands labelled with 131I in vivo. The assay is sensitive to human TSH and gave consistent results during 1 yr. without seasonal variation. A potent preparation of long-acting thyroid stimulator gave a dose-response line parallel with human TSH. Fresh human serum was toxic to the assay preparation so that circulating TSH levels cannot be measured.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.