Abstract

We present a newly designed high-detectivity thermoelectric linear array, based on an organic membrane for use in the room temperature range. The sensor array has 64 individual readable channels and was designed and developed for IR spectroscopy. This detector may be used to infer the condition of lubricants and coolants within a mechanical system, so that they can be replaced when needs be, e.g. determining the age of technical oils of wind power plants in real time. Thus valuable resources can be saved and costly damage to equipment avoided. In order to achieve a D* greater than 2 × 109 cmHz1/2/W, the sensor was designed and optimized to be operated under vacuum conditions. To minimize the thermal cross talk between individual pixels, the pixels are separated from each other by a 50 μm slit in the self-supporting organic membrane made of SU-8.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call