Abstract
Seven randomised comparative studies were conducted in healthy volunteers to compare the pharmacokinetic and pharmacodynamic profiles of selegiline hydrochloride in a new formulation designed for buccal absorption "Zydis Selegiline" (1.25-10 mg) with conventional selegiline hydrochloride tablets "conventional selegiline tablets" (10 mg). A total of 156 healthy volunteers participated in these studies. Plasma concentrations of selegiline and its primary metabolites, N-desmethylselegiline (DMS), l-amphetamine (AMT), and l-methamphetamine (MET) were measured using Gas Chromatography Mass Spectrometry (GCMS) and gas liquid chromatography (GLC) assays. Inhibition of monoamine-oxidase type B (MAO-B) and monoamine oxidase type A (MAO-A) activity was determined by measurement of as beta-phenylethylamine (PEA) by GCMS and 5-hydroxyindoleacetic acid (5-HIAA) by High Performance Liquid Chromatography (HPLC) assays. Almost a third (2.96 mg) of a 10 mg selegiline dose in Zydis Selegiline was absorbed pre-gastrically (predominantly buccally) within 1 minute. Mean [SD] area-under-the curve (AUC(0- infinity)) values following Zydis Selegiline 10 mg (5.85 [7.31] ng.h/mL) were approximately five times higher than those following conventional selegiline tablets 10 mg (1.16 [1.05] ng.h/mL). In contrast, plasma concentrations of metabolites were significantly ( p<0.001) lower following Zydis Selegiline 10 mg than following conventional selegiline tablets 10 mg. Plasma concentrations of selegiline and its metabolites increased in a dose-dependent manner over the dose-range Zydis Selegiline 1.25-5 mg. Bioavailability was determined using AUC and peak plasma concentrations (C(max)). The C(max) of selegiline was similar following administration of Zydis Selegiline 1.25 mg (1.52 ng/mL) or conventional selegiline tablets 10 mg (1.14 mg/mL). The range of values for AUC(0- infinity) and C(max) following Zydis Selegiline 1.25 mg were entirely contained within the range following conventional selegiline tablets 10 mg, with a much higher variability of plasma selegiline concentrations occurring after conventional selegiline tablets than after Zydis Selegiline. As expected, peak plasma concentrations for DMS, AMT and MET were consistently lower after Zydis Selegiline 1.25 mg (1.19, 0.34, 0.93 ng/ml, respectively) than after conventional selegiline tablets 10 mg (18.37, 3.60, 12.92 ng/ml, respectively). A significant (r=0.0001) correlation between daily PEA excretion (a measure of brain MAO-B inhibition) and the log-transformed AUC((0-t)) for selegiline was demonstrated. Mean daily PEA excretion was similar following Zydis Selegiline 1.25 mg and conventional selegiline tablets 10 mg (13.0 microg versus 17.6 microg). In contrast, there was no correlation between PEA excretion and selegiline metabolites, indicating that selegiline metabolites do not significantly inhibit MAO-B. Urinary excretion of 5-HIAA (used as a marker for MAO-A inhibition) was unrelated to plasma concentrations of selegiline or DMS following single or repeat dosing of Zydis Selegiline 1.25 mg or conventional selegiline tablets 10 mg. However, comparison of treatment groups revealed a significantly lower excretion of 5-HIAA in the conventional selegiline tablets 10 mg group than in the Zydis Selegiline 1.25 mg group after repeated administration over 13 days. In summary, by reducing the opportunity for first-pass metabolism, the absorption of selegiline from Zydis Selegiline was more efficient and less variable than from conventional selegiline tablets. Compared with conventional selegiline tablets 10 mg, Zydis Selegiline 1.25 mg yielded similar plasma concentrations of selegiline and degree of MAO-B inhibition, but markedly reduced concentrations of the principal metabolites. Thus, the lower but equally MAO-B inhibitory dose of selegiline in Zydis Selegiline 1.25 mg, which is associated with lower concentrations of potentially harmful metabolites, could offer a safer and more predictable treatment in the management of patients with Parkinson's disease.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.