A cost-effective and removable external beam system is set up based on the Oxford Microbeam system in Fudan University. In our external beam system, 7.5-μm-thick Kapton film is used as exit window with a diameter of 3.5mm. The spatial resolution is about 18μm full width at half maximum (FWHM) on a copper grid. As an example, calcium distribution in otolith is present by the external micro-PIXE. In addition, little change can be done to the external system mentioned above for radiobiology experiments. The exit window can be changed from the focal plane to the observation window of vacuum chamber. By calculation, the beam spot size can reach less than 30μm. Since the Oxford type octagonal target chamber is popular among the nuclear microprobe facilities, this method can be provided to easily replace the in-vacuum system with the external system, extending the in-vacuum analysis to external beam analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.