Abstract

No gold-standard investigation exists for laryngopharyngeal reflux (LPR). Multichannel intraluminal impedance (MII)-pH testing has uncertain utility in LPR. Meanwhile, reflux scintigraphy allows immediate and delayed visualisation of tracer reflux in the esophagus, pharynx, and lungs. The present study aimed to correlate MII-pH and scintigraphic reflux results in patients with primary LPR. Consecutive patients with LPR underwent MII-pH and scintigraphic reflux studies. Abnormal values for MII-pH results were defined from existing literature. MII-pH and scintigraphic data were correlated. 105 patients with LPR [31 males (29.5%), median age 60years (range 20-87)] were studied. Immediate scintigraphic reflux was seen in the pharynx in 94 (90.4%), and in the proximal esophagus in 94 (90.4%). Delayed scintigraphic contamination of the pharynx was seen in 101 patients (96.2%) and in the lungs of 56 patients (53.3%). For MII-pH, abnormally frequent reflux was seen in the distal esophagus in 12.4%, proximal esophagus in 25.7%, and in the pharynx in 82.9%. Patients with poor scintigraphic clearance had higher Demeester scores (p = 0.043), more proximal reflux episodes (p = 0.046), more distal acid reflux episodes (p = 0.023), and more prolonged bolus clearance times (p = 0.002). Reflux scintigraphy has a high yield in LPR patients. Scintigraphic time-activity curves correlated with validated MII-pH results. A high rate of pulmonary microaspiration was found in LPR patients. This study demonstrated a high level of pharyngeal contamination by scintigraphy and MII-pH, which supports the use of digital reflux scintigraphy in diagnosing LPR.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call