Abstract

In low output voltage and high output current LLC resonant converter applications, a synchronous rectification (SR) is essential component for high efficiency and high power density. However, stray inductances in MOSFET package and printed circuit board (PCB) pattern make premature turn-off of SR gate and large SR dead time. To compensate the stray inductance effect and increase system efficiency, a hysteresis band dead time regulation control method is proposed. In the proposed control method, SR dead time is regulated to predetermined dead time target regardless of the stray inductances by using a mixed signal, which includes instantaneous drain voltage information and previous cycle dead time information. As a result, the proposed control method can provide lower conduction losses by the dead time regulation and better transient characteristic by the instantaneous drain voltage information. To verify the validity of the proposed control method, 234-W prototype is built and experimented with the proposed controller, which is implemented with 0.25-μm BCDMOS technology.