Abstract

The ultrasonovision image caused by the tool eccentricity can often present two pieces of vertical black strips in the Casing Well. To solve this problem, this paper proposes a correction algorithm of time eccentricity image based on ellipse fitting algorithm. This algorithm firstly utilizes borehole diameter data to fit ellipse and compute ellipse’s center, major axis, minor axis and inclination angle and other parameters, and then uses these parameters to correct eccentrical ultrasonovision time image. The tested results show that the algorithm can accurately fit ellipse and correct the eccentrical ultrasonovision time image, which is very important practical significance on processing the well logging.

Highlights

  • The principle of ultrasound imaging logging technique is to image the surface of the wall by the amplitude and time of ultrasonic echo after the emission of ultrasound to the wall perpendicularly through a rotating energy transducer

  • Since instrument eccentricity is a common occurrence in practical logging process, it is of great significance to find a method to eliminate such dark bands

  • In order to solve the problem of dark bands caused by instrument eccentricity, this paper presents a correction algorithm for eccentric time image based on ellipse fitting method

Read more

Summary

Introduction

The principle of ultrasound imaging logging technique is to image the surface of the wall by the amplitude and time of ultrasonic echo after the emission of ultrasound to the wall perpendicularly through a rotating energy transducer. In order to solve the problem of dark bands caused by instrument eccentricity, this paper presents a correction algorithm for eccentric time image based on ellipse fitting method. The experimental results show that the algorithm is capable of eliminating the dark bands and making the information of the casing surface displayed more clearly. This is of great value for the practical processing of logging data. In the case of a down hole instrument eccentric ultrasonic television image can no longer completely correctly reflect the acoustic impedance characteristics of the wall of well, the echo wave time cannot reflect the size of the well radius, which affects the interpretation and judgment of logging image

The Correction Algorithm of Time Image
The Correction Algorithm
Testing and Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.