Abstract
A newly developed clinical method of indexing tibial torsion uses the medial surface of the tibia as the proximal reference; however, the selection of a specific landmark on the medial surface has not been justified. Three different surfaces relating to the tibial tuberosity were tested using 24 dry tibial bones to determine which provides the most accurate and reliable landmark for use as the proximal reference. The medial surface of the tibia at the inferior point of the tibial tuberosity was the most reliable proximal reference that yielded the highest level of association between the newly developed clinical method and true tibial torsion (r = 0.77). The new method has the potential to describe the anatomy of the leg and to improve the clinical measurement of tibiofibular torsion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the American Podiatric Medical Association
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.