Abstract
We report a prospective series of 101 patients receiving a four-strand semitendinosus-gracilis autograft for anterior cruciate ligament reconstruction using a new bicortical tibial fixation technique with bioabsorbable interference screws. Patients (average age 32 years) were operated on between November 1997 and Mai 1998, and follow-up was at least 12 months postoperatively. The evaluation consisted of history, clinical examination, IKDC score, Cincinnati Knee Score, KT-1000 testing, standardized radiography and magnetic resonance imaging. One hundred patients were available for follow-up. There were two traumatic reruptures 6 and 11 months postoperatively. By IKDC score 87 patients were in groups A and B, 12 in group C, and 2 with a rerupture in group D. Mean Cincinnati Knee Score was 82 (range 46-100), KT-1000 manual maximum at follow-up showed an average difference of 1.7 mm between the sides. Full extension was rapidly achieved in all cases, and flexion averaged 135 degrees . Considering the enlargement caused by the bioabsorbable interference screws, the incidence of tunnel widening was 6.6% on the femoral side and 1.7% on the tibial side. Tunnel widening did not affect the clinical results. Three patients experienced an effusion after more than 6 months postoperatively. There was one infection, which settled without functional impairment after early arthroscopic lavage and intravenous antibiotics. Otherwise no complications occurred. The described technique for anterior cruciate ligament reconstruction combines the advantage of anatomical graft position with sufficient graft fixation. A short intra-articular graft construct with a strong tendon to bone interface was created. Clinically, 87% of patients had a normal or nearly normal IKDC score at follow-up. Magnetic resonance imaging revealed a considerable increase in tunnel area caused by the insertion of the interference screws. On the other hand, the development of a "fibrous interzone" between the graft and the bone tunnel was prevented in most cases. At short-term follow-up the bicortical tibial fixation proved to be efficient even with an aggressive rehabilitation program.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.