Abstract
Conventional weirs are inherited with afflux and submergence of area upstream of the weir. Various weirs of modified plan form have been suggested in the past to enhance their discharging capacity and to restrict the afflux. Presented in this paper are results of the experimental study carried out to investigate the discharging capacity of a sharp-crested triangular plan form weir under free flow conditions in a rectangular channel. The efficiency of the triangular plan form weirs is better than the normal weir and also high for low vertex angle and decreases with the increase of ratio of head over the crest of the weir and crest height due to interference of the water jets downstream. The computed discharge using the proposed equation is within ±5% of the observed ones. Sensitivity of the weir, i.e., change of discharge due to unit change in head is also carried out which indicates that the weir is more sensitive at the low head and low vertex angle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.