Abstract
Demand for electricity, due to the fast growth in urbanization and industrialization, is on the rapid rise. Load shift is a basic method for demand side management (DSM) that can be used by the central controller in buildings and can lead to the maximum use of renewable energy sources, maximum economic benefits, and reduction of peak demand. This paper proposes an algorithm for shifting the flexible loads of four selected appliances with respect to boundary limits for each appliance. A standalone four-story building with different number of occupants is considered to evaluate this algorithm. The algorithm was trained on Richardson model to minimize two objectives including aggregated demand, and the scheduling discomfort. The proposed algorithm led to significant reduction in aggregated peak demand and thereby savings in standalone system investment. The results demonstrated a major reduction in peak demand from 37% to 44% for winter and summer seasons, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.