Abstract

The aim of the study was to evaluate the efficacy of various approaches to correcting and preventing hypotension episodes in patients on maintenance hemodialysis (HD).Material and methods. The study included 35 patients on maintenance hemodialysis in the Dialysis Center "MCHTP No. 1", which is a part of "B. Braun Avitum" network centers in the Russian Federation. All patients underwent an automatic blood pressure (BP) measurement using a machine-inbuilt option device for noninvasive blood pressure measurement. Prior to the study, all patients underwent a clinical test with a "dry weight" assessment and a bio-impedance analysis. The study had a cross-over design: first, all patients were treated using the standard methods for correcting hypotension episodes (at 4 initial procedures). Then, in the following 4 procedures, in addition to standard methods, a computer algorithm was used to automatically regulate the ultrafiltration (UF) rate: the automatic pressure monitoring system (biologic rr comfort) with continuous monitoring of blood pressure throughout the procedure; BP was recorded before and after the HD procedure, as well as at least once every 5 minutes during 3 initial procedures; and starting from the 4th procedure, the intervals were determined by the algorithm automatically. The average blood pressure values were analyzed during the dialysis procedures for the entire observation period. The duration of the study was 3 weeks for each patient.Results. The average predialysis blood pressures in the group with the standard approach to hemodynamic correction were 124.6 ± 27.7 and 74.5 ± 21.1 mm Hg, the postdialysis blood pressures were 114.4 ± 24.4 and 71.3 ± 16.3 mm Hg. With the use of automatic pressure monitoring system, the predialysis and postdialysis blood pressures were significantly higher than those with the standard approach: 133.2 ± 21.3 and 79.3 ± 15.8 mm Hg (p < 0.001 and p = 0.009), vs. 125.7 ± 23.9 and 75.9 ± 18.3 mm Hg (p < 0.001 and p < 0.001), respectively. Upon closer examination of the intradialysis pressure variations, the intradialysis blood pressures were 110.2 ± 17.3 and 68.3 ± 13.9 mm Hg when measured by using the standard approach, and significantly higher: 124 ± 20.5 and 75.9 ± 14.2 mm Hg when the automatic pressure monitoring system was used (p = 0.03; p = 0.02). Also, higher mean arterial pressures were noted: 82.5 ± 13.9 with the standard approach vs.91.5 ± 15.6 mm Hg (p = 0.01) with the automatic pressure monitoring system. Studying UF rates, we found that the UF rate was slightly higher without using the automatic pressure monitoring system (8.0 ml/kg/h vs. 7.9 ml/kg/h). Thus, the new approach used in addition to the standard methods of correcting hypotension was effective and safe. No significant differences were seen in Kt/V values. However, when automatic pressure monitoring system was used in patients, the target phosphate levels were achieved: the inorganic phosphorus value was 1.5 mmol/L when using the UF control algorithm vs. 1.8 mmol/L with a standard dialysis program. However, these data did not reach the statistical significance (p = 0.07).Conclusion. Intradialysis hypotension and high UF rates remain frequent and potentially dangerous complications of HD procedure, which worsen the long-term prognosis of patients on HD, mainly due to the increase in cardiovascular morbidity and mortality. The new approach to the prevention and correction of hypotension by using the automatic pressure monitoring system allows one to reduce the UF rate in a timely manner, preventing the development of hypotension episodes, reducing their rates, and improving the achievement of target blood pressure values, both preand postdialysis, as well as intradialysis blood pressure variations.

Highlights

  • Цель исследования: оценка эффективности различных подходов к коррекции и профилактике эпизодов гипотензии у больных, находящихся на программном гемодиализе (ГД)

  • The aim of the study was to evaluate the efficacy of various approaches to correcting and preventing hypotension episodes in patients on maintenance hemodialysis (HD)

  • In the following 4 procedures, in addition to standard methods, a computer algorithm was used to automatically regulate the ultrafiltration (UF) rate: the automatic pressure monitoring system with continuous monitoring of blood pressure throughout the procedure; BP was recorded before and after the HD procedure, as well as at least once every 5 minutes during 3 initial procedures; and starting from the 4th procedure, the intervals were determined by the algorithm automatically

Read more

Summary

Introduction

Цель исследования: оценка эффективности различных подходов к коррекции и профилактике эпизодов гипотензии у больных, находящихся на программном гемодиализе (ГД). Дизайн исследования был перекрестным: вначале всем больным применяли стандартные методы коррекции гипотензивных эпизодов (первые 4 процедуры), далее в дополнение к стандартным методам в следующие 4 процедуры у них был проведен компьютерный алгоритм для автоматической регуляции скорости ультрафильтрации (УФ) – АСКД (автоматическая система контроля давления) с постоянным мониторингом АД на протяжении всей процедуры (АД фиксировалось до и после процедур ГД, а также как минимум 1 раз в 5 минут первые 3 процедуры, а начиная с 4-й процедуры, интервалы определялись алгоритмом автоматически.) Анализировались показатели усредненного АД в ходе процедур диализа за весь срок наблюдения. При применении АСКД пред- и постдиализное АД статистически значимо было выше, чем при стандартном подходе, и составило 133,2 ± 21,3 и 79,3 ± 15,8 мм рт.ст. Ключевые слова: хроническая болезнь почек 5Д, осложнения гемодиализа, интрадиализная гипотензия, гемодиализ, клинические исходы, мониторирование артериального давления, артериальное давление, темпы ультрафильтрации, адекватность диализа, кардиоваскулярные осложнения

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.