Abstract

This study investigates a new air-washing cleaning system that directly injects compressed air on the filter surface for filter regeneration in a fabric filter (FF) dust collector. A pilot-scale FF is designed to test the new system and to compare it with the conventional pulse-jet cleaning system with regard to filter clogging by fume particles. A pleated filter with a filtration area of 2.4 m2 is installed in the FF and a thermal steel spraying gun is used to supply the fume particles. Pressure drop and particle emission concentration are monitored to examine the effect of the new system on filter regeneration and collection efficiency. The results show that the air-washing cleaning is effective for filter regeneration, as it allows the FF to operate stably for a long time, whereas the pulse-jet cleaning fails to achieve filter regeneration, resulting in a continuously increasing pressure drop. In addition, air-washing cleaning shows better performance on collection efficiency than the pulse-jet cleaning method, as it reduces the outlet particulate matter concentration to less than half that of the pulse-jet cleaning.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.